IEC 61000-4-30 Ed3 Certification Testing
 

Siemens
Fluke
PSL
Schneider
Electro Industries - GaugeTech
Qualitrol
AEberle
*Listed vendors are certified for Ed2

Power Standards Lab provides third-party testing and certification services for the best power quality instruments in the world.

We approach the certification process as fellow engineers, not policemen. Almost every instrument we've tested has required various firmware adjustments to pass, and we're glad to help your engineers understand exactly what's required.

PSL Test Reports are detailed technical documents that are intended for use by our client's engineers. PSL Certificates are straightforward declarations by a trusted third party (PSL) that an instrument meets certain requirements. PSL Certificates are generally distributed by our clients to their customers.

Upon successful completion of a 61000-4-30 Compliance Report, PSL will issue a certificate for Performance Class A or Class S. In some cases, a single certificate may include different classes of performance for different parameters.

The Certificate applies to all instruments of the tested type or design; it is not necessary to re-test or certify each instrument.

Sample Report

Sample Certificate

Why use 61000-4-30?

More and more customers and end-users around the world require a PSL Class A certification for all their new PQ measurement instrument purchases.

This standard ensures that different PQ instruments use the same definitions, and measurement techniques, for various power quality parameters: sags/dips, swells, frequency, harmonics, flicker, etc.

Older, non-compliant instruments often use their own definitions. As a result, two non-compliant instruments may produce very different readings for the same event.

Getting Started

Click here to download our Annex and answer some questions pertaining to your instrument.

Complete the Annex and send it to [email protected].

Download and complete the form, then email it to
[email protected]
PSL Annex
What is 61000-4-30? Why use 61000-4-30? Getting Started Test Dates & Pricing

What is IEC 61000-4-30 Ed3:2015?

IEC 61000-4-30:2015 defines the methods for measurement and interpretation of results for power quality parameters in a.c. power supply systems with a declared fundamental frequency of 50 Hz or 60 Hz. Measurement methods are described for each relevant parameter in terms that give reliable and repeatable results, regardless of the method’s implementation.

This standard addresses measurement methods for in-situ measurements. Measurement of parameters covered by this standard is limited to conducted phenomena in power systems. The power quality parameters considered in this standard are power frequency, magnitude of the supply voltage, flicker, supply voltage dips and swells, voltage interruptions, transient voltages, supply voltage unbalance, voltage harmonics and interharmonics, mains signalling on the supply voltage, rapid voltage changes, and current measurements.

Emissions in the 2 kHz to 150 kHz range are considered in Annex C (informative), and over- and underdeviations are considered in Annex D (informative). This third edition cancels and replaces the second edition published in 2008


Parameters include:


  1. Power frequency
  2. Magnitude of Supply Voltage
  3. Flicker
  4. Supply Dips/Swells
  5. Voltage Interruptions
  6. Unbalance
  7. Harmonics
  8. Interharmonics
  9. Mains Signaling
  10. Under- and over-deviation

New in edition 3!

  1. Rapid voltage Changes
  2. Flicker Class F1
  3. Measurements in the 2kHz-150kHz frequency band
  4. Magnitude of the Current
  5. Current unbalance
  6. Current harmonics
  7. Current Interharmonics
  8. Recording of current along with voltage during events



What is new in Edition 3:
Edition 3 cancels and replaces the Ed2 published in 2008.
Edition 3 has introduced methods for measuring rapid voltage changes (RVC), currents (amplitude, harmonics, interharmonics, current recordings during events and unbalance), informative methods to measure in the 2kHz-150kHz frequency band

There are 2 classes of performance:

Class A
Instruments that meet Class A performance requirements of this standard will, when connected to the same signals, will produce the same results. Class A instruments must meet the highest performance and accuracy requirements in the standard.

Class S
Instruments that meet Class S performance requirements are useful for statistical surveys and contractual applications where there are no disputes. Accuracy and performance requirements for Class S are less stringent than Class A.



Click here to preview or buy the IEC 61000-4-30 standard (IEC Web store)
Click here to preview or buy the IEC 62586 standard (IEC Web store)
61000-4-30

61000-4-30 is an IEC standard that explains exactly how power quality instruments should work. PSL offers a complete test and verification service for this standard.

Test dates and pricing

For scheduled 61000-4-30 Ed3 testing and certification price quotation, please contact [email protected]
Price includes 1 Udin Voltage of your choice (e.g. 230V) at 50 Hz and 60 Hz.

Please allow 8-10 weeks for completion.
During the entire test interval you must make a technical contact available by phone or e-mail.

Next scheduled 61000-4-30 testing date: September 2016.

Questions?

Send an email to [email protected]